Knowledge of the basic provisions of the manual the ability to avoid malfunctions and failures of fike equipment. This section should be completed by the commissioning engineer at handover. Fike corporations producten en diensten zijn goedgekeurd door verschillende bevoegde organisaties en autoriteiten. The twinflexpro2 panel is an intelligent 2wire panel that utilises a conventional type cabling format. Conventional fire alarm and suppression system fike. Fikes policy is one of continual improvement and the right to change a specification. This intelligent 2wire control panel provides 2 circuits or zones capable of holding up to 32 devices. Engineers notes twinflex pro repeater panel engineering and commissioning manual engineers notes cutting threads on okuma lathe. Due to the complexity and inherent importance of a system covering a life protection risk, training on. When used with the twinflex pro panel, the outputs will only come on in a fire condition. Fike user manual a document that contains rules, tips, cautions and warnings regarding the safe and proper operation of the described product. The new fike twinflex pro2 two wire fire alarm system incorporates the market leading multipoint combined smoke and heat detectors with builtin sounders, allowing the whole system to be easily installed using a fire proof cable that only has two 1. Twinflex v3 control panel user guide 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved.
It is important to read this manual fully before commencing installation. Welcome to the sd fire alarms fike twinflex pro panel description part 1 video. Does anyone have the engineering acces code for this panel if you could. Do i need use twinflexpro osp software for installation and commissioning. Welcome to the sd fire alarms fike twinflex pro panel description part 2 video. Fike twinflex 5050002 two zone fire security panel. This time, we have the pleasure to collaborate with one of our main manufacturers. Buy this fike fike 2040001 twinflex multipoint asd detector with sounder. Twinflexpro control panel engineering and commissioning manual 2 fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Repeater panel engineering and commissioning manual.
Whilst every care has been taken to ensure that the contents of this. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. In practice it is far easier for the user to activate a. Unmatched in the industry for sheer versatility and ease of installation, this singlehazard control system boasts incredible power and can be easily configured for use within a wide. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability. The system is classed as analogue nonaddressable due to the architecture used within the design. Fikes twinflexpro 2wire fire alarm system has long been known for its adaptability and costeffectiveness within a variety of applications, big or small, making it one of the most flexible products on the market. Buy fike twinflex pro fire alarm control panels, sounders, detectors and spares from stock at low trade prices, with quick shipping at. Fike twinflex pro enable key pair view full product details. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of. Relay interfacing module with monitored input to provide shutdown and monitoring facilities from the twinflex zone. Repeater panels do not connect to or control any devices. The fike fire security panel is pached full of features which include the ability to tell the difference between detector and callpoint alarms, five hundred event log and the ability to allow detectors and sounders to be installed on a single pair of wires.
Fike twinflexpro2 2 wire 8 zone control panel cpr compliant 5050008. Using the multipoint asd detector as part of the twinflexpro two wire fire alarm system means that when a. Twinflex is the name of the range of control panels and associated devices which together form the fire alarm system installed in the premises, and is derived from the method of wiring whereby trigger. Fike twinflex pro 2 zone fire alarm panel, fire protection. Relay interfacing module with monitored input to provide shutodwn and monitoring facilties from the twinflex zone. This manual is intended as a guide to the engineering and commissioning principles of the twinflex pro repeater panel and covers the system hardware information only. Twinflex multipoint asd detector with sounder product.
Installation and maintenance instructions 2020003 twinflex multipoint detector 2020001 twinflex multipoint detector with sounder 260027 issue 12 general description the multipoint is a plugin type smoke detector that utilises a photoelectric sensing chamber to make a measurement corresponding to smoke density. Software operating instructions discount fire supplies. Twinflex pro is our best selling fire alarm control panel, installed using only one pair of wires per zone and two types of devices multipoint asd detectors with optional sounder and strobe and manual callpoints. Fike twinflex pro2 engineering and commissioning manual. Fike rafiki twinflex 4 zone fire alarm kit white quick specifications. Twinflex and multipoint installation and operating instructions introduction about the manual these installation and operating instructions contain information to enable an engineer to install, commission and operate the rafiki twinflex range of control panels and field devices. This versatile fike twinflex 5050008 fire alarm panel incorporates fikes multipoint detection system using smoke and heat detectors with builtin sounder, allowing the whole system to be installed using. The twinflexpro two wire fire alarm system incorporating the multipoint asd combined smoke and heat detector with optional builtin sounder and strobe, allows the whole system to be easily installed using only one pair of wires per zone. Mounted in a standard double gang box, including two sets of 2a rated spco relay contacts, one monitored input and inbuilt end of line. View and download fike twinflexpro user manual online. Founded in 1945 and headquartered in blue springs, missouri, usa, fike has grown to become a globally recognized supplier doing business with.
Testing fike twinflex multipoint heat detector with solo 460. The checking period can be between 1 5 minutes and is selected at commissioning stage upon. Twinflex pro repeater panel engineering and commissioning manual contents introduction. Control panel fike twinflex srp 001 engineering and commissioning manual. Quadnet duonet repeater panel engineering and commissioning manual 4 introduction this manual is intended as a guide to the engineering and commissioning principles of the quadnet duonet addressable intelligent fire alarm and detection system, and. Twinflex, mulitpoint, fike and fike corporation are registered trademarks of. Twinflex pro control panel user guide 2 fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Capable of running up to 64 devices in total, devices communicating with the panel do so via the twinflex data protocol. The twinflex multipoint asd is a plugin type smoke detector that utilises a photoelectric sensing chamber and a thermistor sensing circuit which enables the device to be configured to a. Here is the threading code i would use for my ospp200l. In this video i show a demo on testing a fike twinflex pro manual call point on a fike twinflex pro fire alarm panel. Twinflexpropanelengcommanual26095911 dd fire alarms.
Fike twinflex pro2 engineering and commissioning manual 80 pages. Fike 2040001 twinflex multipoint asd detector with sounder. Fike recommends spacing detectors in accordance with bs58391. With its unique lcd display, it can display zone location text, an event log and much more. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. View and download fike twinflex pro2 engineering and commissioning manual online. Multipoint detectors in the dwelling zones have the facility to use fikes checkpoint technology. Bafe certification will be sent out from our administration office shortly afterwards. The fike twinflex pro 2 zone fire alarm panel is an analogue nonaddressable panel using a conventional cabling format.
We recommend and install the fike twinflex pro 2 wire conventional fire alarm system range of equipment. Fike twinflex 5050002 is the next generation in two wire fire alarm reliability. Fike encourages input from our distributors and end users on how we can improve this manual and even the pro duct itself. A maximum of 8 repeater panels can be connected to a single control panel.
Please direct all calls of this nature to fike s customer support department at 800 r979 rfike 3453, option 21. Fike 2040001 twinflex multipoint asd detector with. Control panel engineering and commissioning manual 2 fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Fikes policy is one of continual improvement and the right to change a specification at any time. Fike twinflex call point 4020002 with a resettable element. Fike is the experienced, trusted expert in bursting disc technologies, explosion protection, fire alarm systems and fire suppression solutions. This time, we have the pleasure to collaborate with one of. Fike twinflex midland fire online midland fire online. A conventional 2wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist. Shppro is the reliable, conventional fire suppression system for smaller applications.